Part Number Hot Search : 
AK8817 UCA6472 HF3FF CF5705 DM74L 206R56M2 ATS01 CF5705
Product Description
Full Text Search
 

To Download MB3505-BC01 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MCC
Features
* * * * Low Reverse Leakage Current High Conductivity Metal Case Any Mounting Position Surge Rating Of 400 Amps


!"# $
% !"#
MB3505-BC01 THRU MB3510-BC01
35 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
MB-35
B
Maximum Ratings
* * Operating Temperature: -55C to +150C Storage Temperature: -55C to +150C MCC Catalog Number MB3505-BC01 MB351-BC01 MB352-BC01 MB354-BC01 MB356-BC01 MB358-BC01 MB3510-BC01 Device Marking Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
C
MB3505 MB351 MB352 MB354 MB356 MB358 MB3510
E
G AC D + H AC A
Electrical Characteristics @ 25C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element Maximum DC Reverse Current At Rated DC Blocking Voltage I t Rating for Fusing (<8.3mS)
2
IF(AV) IFSM
35.0A 400A
TC = 55C 8.3ms, half sine
J
VF
1.2V
IFM = 17.5A per element; TJ = 25C TJ = 25C TJ = 125C AS
2 INCHES MIN 1.115 .427 .469 .688 .618 .193 .618 .530
A
DIMENSIONS
IR
10A 1mA
It
2
664
DIM A B C D E G H J
MAX 1.135 .322 .563 .730 .658 --.658 .570
MM MIN 28.33 7.80 11.9 17.48 15.70 4.90 15.70 13.46
MAX 28.83 8.20 14.3 18.50 16.71 --16.71 14.48
NOTE
www.mccsemi.com
MB3505-BC01 thru MB3510-BC01
Figure 1 Typical Forward Characteristics 100 60 40 20 10 6 4 2 25C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 .8 1.0 1.2 1.4 10 6 4 2 1 .6 .4 .2 TJ=25C Amps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 40 60
MCC
Figure 2 Typical Reverse Characteristics
80 Volts
100
120
140
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 60
Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
Figure 4 Peak Forward Surge Current 600
50
500 400 300 Amps 200 100
40
30 Amps 20
10 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 C Average Forward Rectified Current - Amperes versus Case Temperature - C 100 150 175 0 1 2 4 6 8 10 Cycles Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles 20 40 00 60 80 100
www.mccsemi.com


▲Up To Search▲   

 
Price & Availability of MB3505-BC01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X